Primary winding transformers - Description
Primary Winding Transformer, WSK, is the perfect choice for low currents in the range 1 A to 100 A.
In the winding transformer is the housing of the transformers made of impactresistant thermoplastic to ensure a highly reliable quality. The terminals of the winding transformers are protected by a cover.
Read more

Current relay RMC-131D
- Differential current relay
- ANSI code 87
- Measurement of 3-phase currents
- Non-stabilised measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- Extra change-over relay contact for signalling
- 35 mm DIN rail or base mounting

Current relay RMC-122D
- Short circuit and over-current
- I>>: 100 to 400 %, I>: 50 to 150 %
- Combined functionality
- Short circuit relay (I>>)
- ANSI code 50 and 51
- Measurement of 3-phase currents
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting

Over-/undervoltage relay, U> and U< RMV-142D
- Under- and Over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Single phase measurement.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting

Undervoltage relay, U< and U< RMV-132D
- Under-voltage (double).
- U<: 80 to 100 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting

Overvoltage relay, U> and U> RMV-122D
- Over-voltage (double).
- U>: 100 to 120 %,U>: 100 to 120 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting

Undervoltage and overvoltage relay, U< and U> RMV-112D
- Under- and over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting

Synchronisation & circuit breaker closing FAS-113DG
- Automatic.
- Voltage regulation
- Breaker-time compensation.
- Synchronisation of generator to busbar
- Circuit breaker time compensation
- Voltage check
- LED indication of status
- LED for activated control
- LED for synchronising signal
- 35 mm DIN rail or base mounting

MTR-4 Multi-transducer MTR-4
- Suitable for all 1- and 3-phase network topologies
- Up to 1,000 VL-L AC input
- Accuracy class: 0.5 or 0.4
- Up to 4 analogue outputs
- Fast response time, less than 50 ms
- Measures more than 50 parameters
- RS-485 serial Modbus communication
- Fully configurable by USB, no aux. supply required
- Universal power supply of 20 to 300 V DC/48 to 276 V AC

Multi-functional protection relay MTR-4P
- Up to 1,000 V L-L AC voltage input
- Up to 20 A AC current input
- Accuracy class: 0.5
- Password protection
- Trip time typically below 50 ms
- Two-stage trip setting
- Start-up delay
- 13 different protection functions
- RS-485 serial Modbus communication
- Fast and simple commissioning and setup from M-set
- Universal power supply of 20 to 300 V DC/48 to 276 V AC
- Marine approval by GL/DNV

Protection & power management PPM 300 PPM 300
- Synchronization
- Marine certified Power Management - ABP: Advanced blackout prevention (32dg)
- PLC logic
- Engine and Generator protection
- Engine CANbus
- Rear mount
- Flexible Hardware
- Additional I/O racks (9 racks)
- Ethernet Ring connection for Power management
- Redundant breaker feedback
- Colour Display
- Emulation
- Marine approval
- Heavy consumer
- Fast load reduction
- Fuel optimisation