3.62.1 | 10/06/2025 | USW3 build revision: 3169 USW3 product database revision: 11593 Corrections - Resolved crash when using certain keywords in search.
- Fixed issue where generators could disappear from the application.
- Addressed drag-and-drop issues in M-Logic.
- Restored missing translations on AGC5C (AGC-4 Mk I).
- Fixed collapsed tags in the trending view.
- Resolved crash when using filters in the AOP logic drop-down.
- Fixed issue where M-Logic content disappeared when filtering and using move line up/down.
|
3.62.0 PDB 11519 | 09/05/2025 | USW3 build revision: 3151 USW3 product database revision: 11519 New features & improvements - Moved display views configuration to a dedicated page.
- Introduced a third party integration page and dedicated IO page.
- Added advanced filtering capabilities, including EIC Viewline and tag-based filters.
Corrections - Improved page behavior for data persistency and automatic data read.
- Standardized behavior when switching between pages.
- Fixed crash when changing password level.
- Resolved issues with data tracer and parameters tree view
- Restored visibility of M-Logic from older ECU 100 controllers.
- Corrected source measurement updates in plant control.
- Fixed permission handling for digital outputs in AGC 150/iE 150 setups.
- Ensured 'start engine' command is visible in application supervision.
- Resolved missing options in the batch file interface.
|
3.61.0 PDB 11353 | 10/03/2025 | New features - Added support for AGC-4 Mk II - 6.20.0.
|
3.61.0 | 07/02/2025 | This update brings new scheduler functionality, significant improvement to comparison tool, support for iE 150 Marine, along with improvements and bug fixes that enhance software stability and performance. New features - Comparison tools have been updated with more compare functions.
- M-Logic search function has been improved including descriptions and faster clearing speed.
- Support for iE 150 Marine variants.
- Live values enhancements.
- New Scheduler page.
Corrections - Added confirmation message when I/O settings are written successfully.
- Resolved access violation errors in configuration, plant emulation and file comparison.
- Fixed configuration issues with CIO 208 modules 4 and 5.
- Corrected batch write issues in combined engine and network configuration.
- Fixed AGC 150 translation prompt issue due to version mismatch.
- Application supervision now shows correct status for active PV.
- Restored missing BTB redundant option for AGC-4 Mk II.
- Fixed special character corruption in translations.
- Resolved translation read issue.
- Fixed "Save All" function in USW 3.60.2.
- Corrected software revision in identifiers.
- Resolved incorrect Inhibit settings.
- Resolved project closing issues in Advanced Protection/ECU & DAVR configuration.
- Updated footer connect name display.
|
3.60.2 | 09/01/2025 | USW3 build version: 2983 USW3 product database revision: 11101 New features - Support of AGC 150 – 1.22.0.
- Support of AGC-4 Mk II - 6.15.0.
- Support of ASC-4 - 4.29.0.
|
3.60.2 | 15/10/2024 | USW3 build version: 2983 USW3 product database revision: 10963 New features - Support of AGC 150 – 1.21.0.
- Improved application supervision in USW-3 for iE 250 systems.
|
3.60.2 | 02/10/2024 | USW3 build version: 2983 USW3 product database revision: 10901. New features - Support of AGC-4 Mk II – 6.14.0
|
3.60.2 | 19/09/2024 | USW3 build revision: 2983 USW3 product database revision: 10810 Improvements - Enhanced the graph to support improved dragging and scrolling for better usability.
- Refined the display of the live bus bar within the USW application supervision for more accurate monitoring.
- Updated the supervision page to enable proper command functionality when solar is added to load points.
- Extended compatibility for Ring busbar configurations to ensure support across legacy PMS IDs for ASC-4 and ASC 150 systems.
- Enhanced translation encoding when writing to AGC 150 controllers for better text accuracy.
- Adjusted the layout to prevent overlapping measurement data when PV / Battery is added to the load point.
- Improved compatibility and consistency across M-Logic versions.
- Refined the handling of modified command register addresses for improved system response.
- Streamlined the AGC 150 firmware upgrade process to reduce delays.
Correction - Corrected symbol display on the PPM-3 Shore device page when using offline files.
|
3.60.1 | 09/07/2024 | USW3 build version: 2925. USW3 product database revision: 10688. New features - Support of AGC 150 version 1.20.0.
|
3.60.1 | 24/06/2024 | USW3 build revision: 2925 USW3 product database revision: 10644 Corrections • Improved the functionality of the "Write to all" parameter. • Ensured compatibility for parameter files between USW 3.59.1 and 3.60.0. • Fixed an issue with the storage of some translation texts in controllers. • Verified and tested batch job stability for CIO in AGC 4 MK I. Changes • Implemented handling for missing Cio.xml files in ASC-4 Battery controllers and others. |
3.60.0 | 03/06/2024 | USW3 build revision: 2912 USW3 product database revision: 10488 New Features • New way of handling translations. • Search Function & Description in M-Logic. • Live value on USW pages. • Live value on ECU & D-AVR pages. Improvements • Improved handling of Power Meter & Inverter Data • Enabling AOP2 based on software package. Corrections • 'Access Violation' error when trying to change the password level. • M logic & AOP Print option enabled. • Menu text overlapping. • Access violation.t. |
3.59.1 | 04/04/2024 | USW3 build revision: 2851 USW3 product database revision: 10229 Corrections • Correction to permissions write during batch write. • AOP-2 emulated button corrected. • M-Logic delay timer was not written to the controller. • M-Logic items in use showing wrong counting. • M-Logic and AOP in use button not showing active M-Logic lines with offline files. • M-Logic and AOP in use button showing wrong interpretation for Virtual event output. |
3.59.0 | 12/02/2024 | USW3 build revision: 2814 USW3 product database revision: 10079 New features - Added separate page for ECU and DVC configuration.
Improvements USW performance improvements: - M-Logic & AOP handling.
- .Trend file handling.
- Parameter tree structure.
- Alarm update in USW.
- USW message pop-up.
- Batch read and write.
- Offline file handling.
|
3.58.0 | 22/12/2023 | USW3 build revision: 2752 USW3 product database revision: 9675 New features - Added support for AGC 150 – 1.18.0.
- Added support for ASC-4 – 4.27.0.
- Added support for AGC-4 Mk II – 6.12.0.
|
3.58.0 | 22/09/2023 | USW3 build revision: 2752 USW3 product database revision: 9374 New features • Added data logging status. • Added dynamic table for PMS lite application supervision. • Dynamic parameter based on configurational value to show relevant parameters. Corrections • Improved batch write function. • Fixed translation issues. • Fixed issue with opening general purpose PID. |
3.57.1 | 07/09/2023 | USW3 build revision: 2715 USW3 product database revision: 9215 Corrections - Batch read and write fixed
- Other bugs fixed
|
3.57.0 | 10/07/2023 | USW3 build version: 2686 USW3 product database revision: 9157 New features - Added offline configuration comparison tool.
- Added new device page for PMS Lite.
- Added new application supervision for PMS Lite.
- Added option to open and save sensor curve file in AGC 150 Engine drive, AGC 150 Engine drive marine, AGC 150 Generator marine, AGC 4 Mk II Genset.
Corrections - Fixed access violation error when function keys F4 and F5 are pushed too quickly.
|
3.56.0 | 27/02/2023 | USW3 build version: 2516 USW3 product database revision: 8789 New features - Live value available from the "Parameters" page in tree view mode.
- New translation files are added to the translation folder.
Changes - Moved "Permissions" icon to the left menu under "Tools". It is still called "Permissions".
- Moved "PID Configuration" icon to the left menu under "Tools". Renamed to "General Purpose PID”.
- Moved "Modbus Configuration" icon to the left menu under "Tools". The name is the same.
- Added "Firmware" to the "Option" page. Renamed "Option" to "Option & firmware”.
- "Device Information" is now available from the "Option & firmware" page.
- Optimised the tree view text.
- Moved "N-Option" icon to the left menu under "Tools". Renamed to "Ethernet Setting (Modbus TCP/IP)".
- Changed "Open & Close" hyperlink to button icon.
- Changed the maximum number of languages for AGC 150 to 8.
- Moved "Translations" from "Configuration" to "Tools".
Corrections - Optimised the menu bars and windows.
- Optimised the connection with the controller.
- Fixed "Write to plant" function.
- Fixed sensor scaling and curve for multi-input AGC 150 DG.
|
3.55.1 | 09/01/2023 | USW-3 build version: 2457 USW-3 product database revision: 8666 New features - Selective reading/writing of M-Logic and AOP.
- CIO configuration moved from pop-up to a dedicated page.
- Parameter tree view improvements:
- Collapsible panels
- Search function
- Parameter number
- Tree structure improved
- New pop-up for disconnect function.
- Support of 5 CIO 308 modules for AGC-4 Mk II.
- Support of 5 CIO 208 modules for AGC-4 Mk II.
- Support of 5 CIO 116 modules for AGC-4 Mk II.
- Multi-input: Added selection for the number of points in the configurable sensor curve.
- Multi-input: Changed open & close text hyperlink to button.
- Translation folder created in app data location with language files.
Changes Corrections - Every time advanced protection parameters are read, the USW reports that the connection timed out.
- Question marks in I/O setup from old controller.
- USW disconnects when another power management unit is missing.
- Code ANSI zero sequence current/voltage corrected in mouse-over text for parameters.
|
3.54.1 | 21/10/2022 | USW3 build version: 2362 USW3 product database revision: 8516 Changes: - USW Connection Handling. - Sensor curve open & close hyperlink text colour. - RMI Type Selection in multi-input available again. Corrections: - Enhanced performance for "Inverterdata". - AGC-4 Mk II function drop-down disabled for breaker feedback. - RMI Scaling in multi-input fixed. |
3.54.0 | 09/09/2022 | USW3 build version: 2320. USW3 product database revision: 8363. New features: - Support of AGC 150 – 1.12.0
- Support of ASC-4 – 4.23.0
|
3.54.0 | 29/08/2022 | USW3 build version: 2320 USW3 product database revision: 8322 New Feature - Added provision to edit and save sensor curves for multi Inputs and CIO
- Added pre-defined sensor curve
- New launcher window
Changes - Left-side navigation menu style
- Change symbol in USW
Corrections - Batch write crash issue.
- Russian language.
- USB driver signing issue.
- M-logic will overwrite other saved items
|
3.53.0 | 30/06/2022 | USW3 build version: 2186. USW3 product database revision: 8174. Changes: - Support of AGC 150 – 1.11.0
- Support of ASC-4 – 4.22.0
- Support of AGC-4 Mk II – 6.07.0
- New Launcher page for selected products.
- New Menu bar for selected products.
- Ability to save and load sensors via customer files
|
3.53.0 | 25/04/2022 | USW3 build version: 2186 USW3 product database revision: 7957 New features: - Added Portuguese (Brazil) localization.
- Reduced repeated lists on the Product Database.
- Button to open/close the M-Logic toolbox.
Changes: - New ProductIDs in USW V.3.53.0.
- Russian language for Views.
Corrections: - USW crashing with Floating-point overflow.
- Expand buttons disappear when using "Copy to the line below" (AGC 4 and AGC150).
- Mismatch column in parameter tab is not present corrections.
- Parameter disappears after changing Parameter 7841.
- Spinedit component resolution does not respect the decimals attribute.
|
3.52.0 | 22/02/2022 | USW3 build version: 2123. USW3 product database revision: 7880. New features: - Added Support for IEEE 1547 on selected controllers.
- Added fields to Identifiers window to meet dataplate requirements of IEEE 1547.
- Added configuration parameters and their graphical representation on the Advanced Protections page.
- Added parameter validation to meet the configuration requirements of IEEE 1547.
Changes: - Changed graph component to support new features and requirements.
- Changed spinedit component to support new features and requirements.
- Identifiers window content is now always read when opening the window.
- Identifiers window now asks for confirmation when it is being closed.
Corrections: - Fixed an issue causing the Inverter Data page to freeze when opening.
- Fixed an issue where the slider value would work irregularly.
- Fixed an issue that caused a crash when the IP address was not available.
- Fixed an issue for an illegal data value error when writing Multi-Inputs.
- Fixed an issue that caused the language selection to not be available.
- Fixed an issue where setpoint 3 was not available for RMI inputs.
|
3.51.0 | 16/02/2022 | USW3 build version: 1978. USW3 product database revision: 7845. New features: - Support of AGC 150 – 1.10.0
- Support of ASC-4 – 4.21.0
- Support of AGC-4 Mk II – 6.06.0
|
3.51.0 | 16/12/2021 | USW3 build version: 1978. USW3 product database revision: 7679. New features: - Support of AGC 150 – 1.09.0
- Support of ASC-4 – 4.20.0
|
3.51.0 | 11/11/2021 | USW3 build version: 1978. USW3 product database revision: 7621. New features: - Support for PMS redundancy on AGC 150.
- Support for AGC 150 Remote Display variant.
- Support for AGC 150 Marine.
Changes: - The device page for AGC 150 Hybrid now shows values for the inverter.
- The supervision page for AGC 150 Hybrid now shows a generator with a PV panel.
Corrections: - Solves an issue that made it difficult to edit numeric fields.
- Solves an issue that made toolbars seem to not be present.
- Solves an issue that caused corruption to special characters on export of Translations to a CSV file.
- Solves an issue on I/O Setup occurring when opening a .usw file of AGC 150 and AGC-4 Mk II.
- Solves reported issues of support for special character handling in several pages.
- Solves an issue leading to errors in the graphs of the VRT tabs in Advanced Protections.
|
3.50.1 | 07/07/2021 | USW3 build version: 1880 USW3 product database revision: 7366 Corrections: - Fixed an issue that prevented users from scaling the multi-inputs.
|
3.50.0 | 09/06/2021 | USW3 build version: 1849 USW3 product database revision: 7312 Changes: - Validation of CIO 208 configuration written to the controller
- In some cases, the controller may reject the configuration set by the user.
- The Write function now reads back from the controller and notifies the user in case of disparity between the user selections and the controller.
Corrections: - Fixed an issue causing failures to read the CIO configuration in Batch Read.
- Fixed an issue where some drivers had a wrong digital signature.
- Fixed an issue where multi-input scaling would change back to "DegC 1/1" after writing to the controller.
- Fixed an issue where Batch Read and Batch Write would not work properly for Multi-input settings.
- Fixed an issue where the RMI configuration would be lost when using the Batch Write functionality.
- Fixed an issue where the Batch job would finish but the pop-up would not accurately depict the progress.
- Other small fixes and performance improvements.
|
3.47.2 | 28/04/2021 | USW3 build version: 1808. USW3 product database revision: 7240. What's new: Support of AGC150 – 1.06.0. New features: - Added AGC150 Engine drive variant.
- Added fallback timer for power limit on SunSpec (parameter 17180).
- Added support for Keyswitch in I/O setup.
- Added support of PV breaker.
- Added EIC and MPU speed to delta alarms.
|
3.47.2 | 25/03/2021 | USW3 build version: 1808. USW3 product database revision: 7181. What's new: Support of AGC-4 – 4.81.0 Support of AGC-4 Mk II – 6.02.0 Support of ASC-4 – 4.16.0 Corrections: - Solves an issue where importing favorites was not working.
- Solves an issue where errors would occur when the PC awakes from sleep mode.
- Solves an issue where the parameters from Advanced Protections would not be consistently written to the controller.
- Solves an issue where AOP 1 and AOP 2 would be written when cancelling the write operation of M-Logic.
- Solves an issue where an Access Violation error would occur when writing to multiple controllers.
- Solves an issue where the "Enable" parameter was not written when writing to multiple controllers.
- Solves an issue where the IP address would disappear from the bottom status line on some controller types.
- Solves an issue where the CIO 116 and CIO 208 could not be configured.
- Solves an issue where an error would occur when selecting CIO 116 on some controllers types.
|
3.47.1 | 12/01/2021 | USW3 build version: 1743. USW3 product database revision: 6991. What's new: • AGC-4 Mk II release: • Support for Application SW download. • New bootloader available for AGC-4 Mk II.
• New I/O setup page for AGC 150 and AGC-4 Mk II: • The I/O configuration toolbar button and respective page have been deprecated for the mentioned products. • The input alarm and relay configuration functions have been removed from the parameter list for the mentioned products. • Digital input and multi-input functions and alarms are now placed in tabs on the I/O setup page, accessible from the main navigation menu on the right side of the window. • Output functions and configuration are now placed in a single tab on the I/O setup page.
• CIO input/output function setup: • Due to the removal of the I/O configuration pop-up, CIO116 and CIO208 functions can be selected in the CIO configuration page. • The support for functions on CIO308 multi-inputs is not supported by this release.
|
3.45.4 | 03/09/2020 | USW3 build version: 1518 USW3 product database revision: 6586 What's new: - Adds support of upcoming AGC 150 Hybrid.
- Adds support of upcoming AGC-4 version 4.79.0.
- Adds support of upcoming ASC-4 version 4.14.0.
Corrections: - Solved issue with CIO alarm setpoint shown as zero.
- Solved issue where AGC 150 multi input alarm delays were possible to set outside the allowed range.
|
3.45.3 | 27/03/2020 | USW3 build version: 1490 USW3 product database revision: 6360 New: - Adds support of upcoming AGC 150 version 1.02.0.
- Adds support of upcoming AGC 150 version 1.03.0.
- Adds support of upcoming AGC-4 version 4.77.0.
- Adds support of upcoming ASC-4 version 4.12.0.
|
3.45.2 | 17/12/2019 | USW3 build version: 1471 USW3 product database revision: 6257 New: - Adds support of upcoming AGC-4 version 4.75.0.
- Adds support of upcoming AGC-4 version 4.76.0.
- Adds support of upcoming ALC-4 version 4.10.0.
- Adds support of upcoming AGC 150 version 1.01.0.
Corrections: - Solves an issue where the Multi Input alarm inhibits from a stored usw-file, was changed to zero before written to the AGC 150.
- Solves an issue with wrong scaling on Multi Input: Alarm Set points for input types: PT100 and RMI Fuel level
- Solves an issue with wrong scaling on Multi Input: Curve Set points for input type = RMI Water temp.
|
3.45.1 | 29/08/2019 | USW3 build version: 1439 USW3 product database revision: 6109 Corrections: - Solves an issue where the firmware could not be downloaded to the AGC 150 via TCP/IP if the PC and the controller were not on the same subnet.
- Solves an issue with wrong scaling on droop curve 2 parameters.
|
3.45.0 | 06/05/2019 | USW3 build version: 1430 USW3 product database revision: 6024 New Features: - Support for configurable 5 line display view in AGC 150 series.
- Support for AGC 150.
- Firmware update USB and LAN - Bootloader update - New Multi-Input setup page - New Navigation icons - Support of ASC-4 Load Point connection in Power Management applications.
Improvements: - Commissioning view in Parameter removed when irrelevant to parameter
- Trending settings are now allowed to be down to 20 ms (0.02s) polling.
- Note: Controller may not be able to deliver data at this rate. Corrections: - Solves an issue where the Log page would no read all log lines.
- Solves an issue where plant read/write would fail in some occasions.
- Fixes the command line parameter for Advanced protections.
- Solves an issue introduced in USW v.3.44.0 where the "M-Logic and AOP items in use" window would not show all information.
- Solves an issue where parameters could be missing in the batch (.usw) file.
- Solves an issue introduced in USW v.3.44.0 where the AOP2 configuration could fail.
- Solves an issue where Beckhoff modules outputs were missing on the GC-1F.
- Solves an issue where the ASW is not shown when writing batch file on the AGC100.
- Fixes the battery colour in Application Supervision.
|
3.44.1 | 21/01/2019 | USW3 build version: 1386 USW3 product database revision: 5778
Corrections 1. Advance protection Print and print preview 2. Power management now showing in M-Logic & AOP Events 3. M-Logic offline file can be opened without connecting to controller 4. Sequence CIO and PID has been changed while batch writing |
3.44.0 | 06/12/2018 | USW3 build version: 1372 USW3 product database revision: 5733 New Features: - M-Logic & AOP
- M-Logic and AOP configuration are now organised in tabs on the same page. - The AOP configuration pop-up is changed to work as an AOP mimic (ASW > 4.60.0). - Added a visual representation (diagram) of the logic blocks selected in the logic line. - Added a toolbar for easy drag-and-drop of Events and Outputs to the logic lines. - Dynamic M-Logic and AOP are now evaluated on the logic lines diagram. - Parameters - Sets of Favourites
- Users can create/modify/delete sets of Favourites under the Settings page. - Users may Import/Export Favourites sets in settings under the Settings page. - Users can categorise parameters into different sets of Favourites. - Favourites filter has now a drop-down menu for selecting from the available sets of Favourites. - Parameters – Parameter management
- Users can now perform selective saving and writing of parameters. - A new indicator help users to identify parameters that were edited, but not written. - Users can now filtrate the parameter list for edited parameters. - Advanced Protections configuration page for options A1, A10, C2 (ASW > 4.70.0)
- Command line
- It is now possible to merge parameter files with the command line interface. - Merged parameters can be written to a file or written directly to a controller. Improvements - USW is now an available application to select from on Windows side-by-side view.
- ALCs can now be added to the left of Mains.
- Performance improvements in reading parameters (after first read).
Corrections - Fix for batch read/write and backup/restore for PID settings and ID.
- M-Logic not displayed in USW3 under content in .usw file
|
3.43.2 | 27/09/2018 | USW3 build version: 1236 USW3 product database revision: 5599 New - Adds support of upcoming AGC-4 version 4.68.0.
- Adds support of upcoming AGC 200 version 4.68.0
|
3.43.2 | 12/06/2018 | USW3 build version: 1236 USW3 product database revision: 5477 New - Adds support to the upcoming release of ASC-4.11.0
- Adds support to the upcoming release of AGC-4.67.0
Improvements - Changes the naming of output tab in parameters to ‘Outputs’
Fixes - Fixes an issue in AGC 200 M-Logic where Ventilation mode and Dry mode were not working.
|
3.43.2 | 15/05/2018 | USW3 build version: 1236 USW3 product database revision: 5368 Corrections: - In some cases where the OS was localised, the utility software was wrongly showing a debug version message.
|
3.43.1 | 16/03/2018 | USW3 build version: 1222 USW3 product database revision: 5368 New features: - QR code for options upgrade
- Visual updates in application supervision
- Command buttons for DG units in supervision
- Click on unit to open its command panel
- Up to 8 configurable values may be added for each ID in supervision (only units configured on top or bottom of area)
- Sorting I/O in alphabetical order
- Duration of mouse-over texts is now configurable
- USW now stores the parameter view settings so that it opens in same view next time
- Support of AGC-4 version 4.66.0
- Support of ASC-4 battery controller
Changes: - Various updates related to ALC-4
- Various updates related to ASC-4 PV
Corrections: - In some situations, the USW would not show the correct application and breaker positions
- ASC Battery: When drawing a stand-alone application for ASC Battery with only the battery, the colours are wrong
|
3.42.0 | 12/10/2017 | USW3 build version: 1164 USW3 product database revision: 5223
New features: - Support of AGC-4 and AGC 200 version 4.65.0
- Support of new power meters on ASC-4
Corrections: - Corrected: AGC 233 parameters not shown
- Corrected: Emulation in AGC 200 and AGC-4 not working
|
3.42.0 | 01/09/2017 | USW3 build version: 1164 USW3 product database revision: 5181 New features: - Radio Ripple Control Receiver (RRCR) communication support for ASC-4/ASC PM
- Option N will create exceptions for firewall, but only if the user is admin. This will be handled in the installation file
- Includes reliability data in USW files
- Dynamic evaluation added to AOP-1 and AOP-2
- Navigation in the USW even when AOP window is open
- Text representing the regulator mode
- "Save All" files function on the USW
- Support of new ID configuration
- Shows SIPC number in USW3 when USW is built/used for an SIPC
- Possible to zoom in and out in the plant view
- Support of digital I/O in trending
- Support of trend only mode
Changes: - Inverter data support updated for ASC-4, ASC PM
- Improved dialogue when changing between units
- Application supervision unit ID on PV and LG
- CIO inputs column in the Inputs/Outputs list is made wider
- Possible to multiply the trending values so they match the CIO configuration
Corrections: - Strange pop-up during connection to a genset group tie removed (build 1092)
- CIO added to OEM product IDs
- Unconfigured TB is no longer shown
- Corrected: Remote maintenance M-Logic missing (option H12)
- Translation no longer reveals passwords
- Option H13 added in option overview
- MB is no longer shown when opening a batch file when it is not present
- List of CIO 308 cold junction inputs is now updated when reconnecting the USW
- Unit scaling and RMI sensor type are aligned
- Russian translation of RMI corrected
- "Active alarm log" can be pulled up again after minimising
- Dialogue box no longer keeps the existing M-Logic text
- M-Logic no longer disappears during batch reading
- AGC 100: Writing phone numbers with a batch write no longer results in strange characters
- Possible to write CIO parameters with batch file
- BTBs can no longer be misplaced in application drawings with ASC/ALC
- Power management ID selection logic corrected, when using new IDs
- M-Logic event C drop-down list now always opens
- Logged alarm values are now scaled correctly
|
3.41.2 | 03/04/2017 | USW3 build version: 1119 USW3 product database revision: 4980 New features: - Support of AGC 222 OEM variant
|
3.41.0 | 25/11/2016 | This software applies to the following DEIF products: - GC-1F v.1.xx
- Multi-line 2 - AGC v.3.xx
- Multi-line 2 - PPM v.3.xx
- Multi-line 2 - PPU v.3.xx
- Multi-line 2 - GPU v.3.xx
- Multi-line 2 - GPC v.3.xx
- Multi-line 2 - AGC 200
- GC-1F ATS
- GC-1F/2 v.2.xx
- Multi-line 2 - AGC v.4.xx
- Multi-line 2 - GPU-3 REC ver. 3.xx
- Multi-line 2 - AGC 100 v. 4.xx
- Multi-line 2 - CGC 200
- Multi-line 2 - CGC 400
- Multi-line 2 - ECU 100
- Multi-line 2 - GCU 100
- Multi-line 2 - PPU v.3.xx Marine
- Multi-line 2 - GPU v.3.xx Marine
- USW3 build version: 1056
- USW3 product database revision: 4805
Changes: - Additional product database updated to support AGC-4 v.4.59.0.
- Alarm set point range of CIO 308 Pt100/Pt1000 inputs extended.
- Please note: Only the configuration files have changed.
New features: - Support of CIO 116, CIO 208 and CIO 308
- Support of ALC-4 and ASC-4
Changes: - Serial number made mandatory, in the option key generator.
- Product database updated to support AGC-4 v4.59.0
- Product database updated to support AGC 200 v4.59.0
Corrections: - Voltmeter on device page corrected
- Buttons placed correctly in tree view
- AGC 100 "Counters and identifiers" issue corrected
- Various corrections to option N software
|
3.40.1 | 06/07/2016 | 40.1 06-07-2016 Changes: - 1- Product database updated to support AGC-4 v4.57.0
- 2- Product database updated to support AGC 200 v4.57.0
- Please note: Only the configuration files have changed...
- 3.40.1 06-06-2016
Changes: - Product database updated to support ASC PM Solar v5.06.0
- 3.40.1 31-05-2016
Changes: - Product database updated to support AGC-4 v4.56.0
- Product database updated to support CGC 412 and CGC 413 v1.13.1
- Minor product database updates to AGC 252
- 3.40.1 21-12-2015 Changes:
- Added support for AGC 252
Corrections: - PPM-3: In USW application configuration, two EDGs could be drawn, while only one EDG is supported in an application.
- Please note: Only the configuration files have changed...
3.40.1 27-11-2015 Changes: - Updated Product Database for various products
- 3.40.1 01-07-2015 Corrections:
- USW 3.40 - F3 connection menu is not working for new users
|
3.40.0 | 24/06/2015 | New features: - Support of AFC PM (Automatic Fuel Controller).
- Support for Windows 8 - language selection.
- Support for 1/10000 in units.
- Translation tree.
Changes: - CAN line names - use of primary and secondary instead of A and B.
- Grey out of button for “activate plant configuration”, if only single unit application.
Corrections: - Russian language causes PDF export to fail.
- Parameter texts on shared channels updated correctly.
- Missing “edit notification” in list view, after parameter change in tree view.
- Translation issues for CGC 400, AGC 100 products.
- Missing connect icon in emulation mode.
- Digital status page not updated correctly.
- TB missing in USW 3.39.0 application supervision.
- GC-1F/2 ASW 2.31.1 Application configuration should not be visible.
- AGC-3 Dual mains application configuration is not working.
- TB appearing in old application drawing when shown in newer USW version.
- Batch read from M-Logic tab not successful.
- IP address – leading zeros.
- Chinese M-Logic PDF export.
- MB present when none is configured.
- AGC 100 emulation option problem.
- Import translation from file.
|
3.39.0 | 19/09/2014 | Re-location of USW 3.39.0 - link to NTP-patch included 3.39.0 26-09-2014 NTP patch for USW 3.39.0 A patch is needed to make the NTP-configuration work. In future releases this won’t be necessary. 3.39.0 26-09-2014 NTP patch for USW 3.39.0 A patch is needed to make the NTP-configuration work. In future releases this won’t be necessary. 3.39.0 26-09-2014 Re-location of USW 3.39.0 - inclusive link to NTP-patch. New features: - Support of ASC PM (Automatic Solar Controller).
- Support of Qc1103.
- Support for firmware download to webarm hardware with new flashes mounted.
- Support for configuration of NTP in webarm from ver. 2.40.0.
Changes: - Possibility to change Loginfo scaling factor.
- Change of bit mask when writing inhibit configuration to device.
Corrections: - Access level update
- CGC 400 - missing Russian letters for translation
- Russian language support now working 100%
- USW 3.38 usw files not recognised by Windows.
- PPM-3 cannot open batch files "File format error"
|
3.38.0 | 11/06/2014 | New features: - Update boot SW (Standard ML2 ver. 3 products)
Corrections: - PPM-3 display of power measurement
- USW 3.37.0 freezes when connecting to PPM unit
- CGC 200: default parameters available before reading from device
- CGC 200: Parameter editor - dropdown list value selection
|
3.37.0 | 01/04/2014 | New features: - Support for extended Chinese characters in CGC 400
- Support of AGC PM product
Changes: - Scaling in Trending - Default setup and possibility to choose alternative
|
3.36.0 | 23/12/2013 | New features: - Parameters: Tree view for AGC 100 variants
- Parameters: Reloading of dependent parameters for AGC 100 variants
- Support of firmware upgrading over a TCP-IP connection if the AGC-4 is version 4.40, the option N has version 2.20 and the boot code has version 1.03.0
- Communication: Faster communication over TCP-IP if the option N has version 2.20
- Communication: Network parameter pop-up to easily set the IP address, netmask and gateway if the AGC-4 is version 4.40 and the option N is version 2.20
- Logs: Support of up to 500 alarms and event log lines
- Views: Tree view of the Views items
- Identifiers: Display of boot code and option N firmware version
- Identifiers: Display of production info like serial number, order number and production date
Corrections: - Faster communication over USB when a parameter pop-up is open
|
3.35.0 | 30/08/2013 | New features: - Project Properties: Store user-defined comments as part of usw file
- Project Properties: Display the firmware version from which the different components inside the usw file originate
- Alarms: Double-click an alarm and open the corresponding parameter
- Parameters: Alarm status is updated while a parameter popup is open
- Parameters: Simultaneous display of multiple parameter popups
- Parameters: Export/import of the list of favorite parameters
- Parameters: Inhibits column added to the list view
- Parameters: Favorite and Modified-Parameter filters work in tree view as well (AGC-4 and AGC 200)
- Parameters: Reloading of dependent parameters (AGC-4 and AGC 200)
- Parameters: For selected parameters the Output A & B values are shown in the tree view mode (AGC-4 and AGC 200)
- Parameters: Display the parameters for the AGC 200 in a tree-like structure
- Logs: Open .sdl files originating from the flashcard in AGC 200
- New USB driver for CGC 200 and CGC 400 variants.
Corrections: - The application retrieved during the initial connection to GCU 112 does not cause an error message
- Identifier texts with Unicode characters are not written correctly to AGC 200 products
|
3.34.1 | 08/05/2013 | Corrections: - The firmware flashing of the CGC 200 works on all PCs
- Scaling is working correctly for controllers configured to different power and voltage scalings
- Cos phi is removed from the Electrical data window for PPM controllers
- The apparent power (S) in the Electrical data window is correct for PPM controllers
- The offline Batch-read procedure is working correctly
- The data fields in the Electrical data no longer appear to be editable
|
3.34.0 | 20/03/2013 | New features: - Support of the CGC 200 and CGC 400 variants
- Support of the AGC 100 variants
- Support of the AGC 200 firmware 4.21
- Support of the ECU 100 and GCU 100 variants
- Install script updated:
a) shows EULA b) displays the USB installation popups sequentially c) CGC 200 USB driver added - Supervision: Display of all available electrical data for the controllers in the application
- Supervision: Emulation support in a broad range of products (AGC 100, AGC 200 firmware >= 4.21,ECU and GCU 100 variants)
- Supervision: Save a screen copy to a graphical file
- Supervision: Plant settings popup for easy access to parameters often changed after commissioning (applies only for AGC-4 and AGC 200 variants)
- Parameters: Display of parameters in a tree-like structure (applies only for AGC-4 variants and CGC 200)
- Alarms: Acknowledge of alarms individually
- Chinese localisation
Changes: - Connecting to device procedure is more intuitive
- Alarms: Display of current alarms and alarm history
Corrections: - The writing of Translations has been improved
- M-Logic and AOP lines have a consistent numbering in the relevant popups
- Read logs from GC-1F no longer fail
|
3.33.0 | 09/10/2012 | New features - Support of redundancy (AGC-4 only)
- Indication of the parameters that have been changed since commissioning (AGC-4 only)
- Display in Appl. Supervision of the names assigned to engines, breakers and mains (AGC-4 only)
- Possibility to reset logs in the controller (AGC-4 and AGC 200 only)
Changes - M-logic page is empty initially
- M-Logic page adjusts to the width of the window
- Device page can handle negative power values
Corrections - Batch write issue regarding Modbus configurator data was fixed
- Application Configuration page does not show “AGC” in the header initially
- Service level user can change the access level of any parameter to any lower level
- Data tracer will show the same number of digits as in the Trending window
|
3.32.0 | 07/06/2012 | Install script updated to remove temporary files, which can cause problems during installation New features: - The Connect Symbols are shown in Application Supervision to indicate the connected controller
- The texts assigned to digital inputs are shown in the Emulation inside Application Supervision
- Printout of Engine and Genset data in Application Supervision
- Applications are presented in tabs in Application Configuration
- Improved user interface to perform activation and broadcasts of applications
- Customisation of column widths in Parameter and Translations pages
- Execution of selected functions at the Windows Command prompt
- Automatic adjustment to the baud rate of the controller
- Faster batch writing of languages as those not translated are skipped
- Parameters can be tagged as favorites and a favorite filtering in the Parameter list can be applied
- The access level can be changed for a selected list of parameters
- Which columns to show and the sequence of these can be customised in the Parameters page
- Only enabled M-logic lines are shown on printouts
- Counter and Identifiers information can be printed
Changes: - Properties of the following products were updated: AGC-3, AGC 200, PPM-3, AGC-4, GC-1F/2, PPU-3, PPM-3, GPU-3, GPC-3, GPU-3 REC, APU 264
Corrections: - For the PPM-3 the terminal numbers given in the I/O page are correct
- Only Modbus ids in the range 1..247 are allowed
- Various improvements in the Color Scheme Editor in Supervision
- The configuration made with the Modbus Configurator can be stored as part of an usw file
- Breaker in Device page of APU 264 is updated correctly
- Older PPM-3 firmware no longer cause errors in USW 3
- Choosing the language to activate after doing translations also works with TCP-IP connection
|
3.30.1 | 07/12/2011 | Changes: - Supervision page is updated consistently according to active application.
- Batch read/write improved when offline.
- The correct access levels are applied for GC-1F.
- Edition of Energy counters improved.
- USW no longer claims exclusive access right to files.
|
3.30.0 | 08/11/2011 | New features - Support of the new controller AGC-4
- Counters: read-out of various counter values from the controller
- Identifiers: read-out of various id’s used the controller
- Dynamic M-Logic evaluation: the values for the M-Logic lines are evaluated on-the-fly
- AOP and M-Logic lines in use: provide an overview of where different event types are used in the logic lines
- Batch read: allows the read-out of logs and export to Excel file format
- Backup/restore: backup a controller for later restoring
- Translations: Prompt for selection of which language to set active after the writing of translations
- The language of the USW 3 application can be set to Russian
- Support for automatic reconnection after firmware flashing
- Display of all controller views at the same time
- A time offset used during synchronizing the time of the PC with the controller can be set
- Explicit scanning for available COM ports
- Emulation of a plant and response to e.g. inputs
- Deep dive allows to navigate between the upper and lower levels of option G7 based plants
- Permission: control which access levels can do what
- Display of the engine data retrieved over j1939 by the controller
Changes - Only buttons and menus relevant for the offline situation are shown at startup of the USW 3
- During batch read/write the sequence of items is changed
- The help functionality has been updated with the new features listed below
- An issue regarding the sending of emails and/or SMS’s from the N-option is fixed
- In offline mode the Device page corresponding to a open file is shown
- User is prohibited to enter invalid IP address in the N-Option application
- Setting of the trending update rate is fixed
- The offline writing of view is no longer, mistakenly, reported as successful
- Logs: order of first two columns Timestamp and Text is switched so Timestamp goes first
|
3.21.0 | 15/04/2011 | - New features
- AOP, Views and I/O Settings buttons in the top toolbar are active if connected to a device or an USW file with corresponding information is loaded.
- Support of GPU-3 REC
- Support of GC-1F ATS
- Support of AGC 222
- Support of various new parameters in PPM 3.05
- The application Modbus Configurator is added as part of the USW installation. This application is used to perform a memory mapping to the configurable memory area in the devices.
- Application Settings: Functions to clear the settings that the USW saves from session to session
- Option Wizard: Last entered customer information is displayed as default
- Project properties: Option- and hardware configuration can be copied to clipboard
- In Batch Read/Write a new shortcut, Ctrl-A, selects all items Changes
- Translations written from a Chinese PC: the issue, where the character "?" was shown in GC-1F variants is fixed.
- Terminal numbers in the Inputs/Outputs page are corrected for AGC-3.
- Application Configuration is handled before Parameters during Batch Read/Write operations.
- Cyrillic K (К) handled properly
- Removal of “Generate random data”
- Supervision: “Engine data” was renamed to “Genset data”
- Writing of the netmask (AGC2xx products) is fixed.
- M-Logic dropdowns are always repopulated when connecting to another device type
- When logs are exported to Excel also the timestamps are saved in the file
|
3.20.0 | 04/02/2011 | New features - Support of the new product GC-1F/2
- Support of the new products APU-3, APU 264
- Move and copy items in M-Logic
- List of existing ports is displayed in communication setting popup
- Connectivity check in Supervision (require AGC firmware 3.6 and above)
- Compatibility check in Supervision (require AGC firmware 3.6 and above)
- Engine data in Supervision (require AGC firmware 3.6 and above)
- Cyrillic display option (CYD) shown in Options
- Terminal numbers shown in Input/Outputs
- Tooltip texts for parameters
- USW files can be shared among selected products series:
- AGC 212, 213, 232, 242, 243
- AGC 245, 246
- GC-1F and GC-1F/2
- List of keyboard shortcuts is extended
- Subnet mask can be edited for AGC 200 series if supported by product (require AGC firmware 3.6 and above)
- Device flashing and clock synchronization as part of the optional batch write steps.
Changes - Improved scaling in the Device page of PPU-3, GPU-3, GPC-3, GPC-3 Hydro
- Updated Help functionality
- Installation on Windows 7 does not require administrative rights
- More intuitive tabing order in M-Logic
- Colour scheme editor and color scheme selection joined in the same popup
- Improved scaling of meters on Device page for GC-1F
|
3.16.0 | 24/08/2010 | New features - Import translations from file into selectable columns in Translations.
- Assign language names to translations columns.
- Change the sequence of the language columns in Translations.
- Copy language columns to other columns in Translations.
- Full 64 bit support:
- Signed USB driver for AGC 200 for 32 and 64 bit Windows platforms (XP, Vista and 7).
- Signed USB driver for AGC-3, PPM-3, PPU-3, GPU-3, GPC-3, GPU-3 Hydro for 32 and 64 bit Windows platforms (XP, Vista and 7)
- Drag-‘n-drop of USW file onto the USW application.
- Led or button number is shown in the header of the AOP item popup.
- User confirmation when writing AOP1, AOP2 or M-Logic.
Changes - Updated Option wizard.
- Improved support of translations in AGC 200 series.
- Improved writing of translations.
- Improved support of Applications with a ring-shaped bus-bar.
- Improved error handling during writing of translations to GC-1F.
- Support of PPM 3.04.
- Support of new parameters for PPU-3, GPC-3, GPU-3, GPU-3 Hydro.
- Updated Help functionality.
|
3.15.1 | 07/05/2010 | Changes (USW 3.15.1) - Writing of M-Logic, AOP1 and AOP2 configurations are password protected.
- Enabled flags are written correctly when writing parameters.
- New features (USW 3.15.0)
- Support of AGC 200 variants which includes:
- Unicode text support in Translations
- Retrieval of logs
- Firmware upgrading
- Configuration of TCP/IP network parameters
- New USB driver
- Export of reports to PDF
- Support of voltage and power scaling in PPU3, GPU 3 and GPC 3
- M-Logic/AOP improvements:
- Color symbol to indicate the Enabled state of each line
- Optional user-defined description field for each line
- IP address edited in Settings dialog box through combobox with auto completion
- Plant Option dialog box: In offline mode the Product type is selected from a list of product families
- Batch Read/Write can be cancelled
- Save Application Configuration to jpeg file
- Installation file is digitally signed
Changes (USW 3.15.0) - Increased Parameter writing speed
- Single DB application colored correctly
- Batch jobs: The caption shows whether it is a read or write batch job
- Improved export to Excel file format (content and format)
- Improved device filtering to prohibit writing of parameters from one device type to another
- Writing of M-Logic, AOP1 and AOP2 configurations are password protected
- Number of languages written in Translations cannot exceed the max allowed by the device
- Ring connected busbar is handled consistently
|
3.15.0 | 05/05/2010 | New features - Support of AGC 200 variants which includes:
- Unicode text support in Translations
- Retrieval of logs
- Firmware upgrading
- Configuration of TCP/IP network parameters
- New USB driver
- Export of reports to PDF
- Support of voltage and power scaling in PPU3, GPU 3 and GPC 3
- M-Logic/AOP improvements:
- Color symbol to indicate the Enabled state of each line
- Optional user-defined description field for each line
- IP address edited in Settings dialog box through combobox with auto completion
- Plant Option dialog box: In offline mode the Product type is selected from a list of product families
- Batch Read/Write can be cancelled
- Save Application Configuration to jpeg file
- Installation file is digitally signed
Changes - Increased Parameter writing speed
- Single DB application colored correctly
- Batch jobs: The caption shows whether it is a read or write batch job
- Improved export to Excel file format (content and format)
- Improved device filtering to prohibit writing of parameters from one device type to another
- Writing of M-Logic, AOP1 and AOP2 configurations are password protected
- Number of languages written in Translations cannot exceed the max allowed by the device
- Ring connected busbar is handled consistently
|
3.14.0 | 28/12/2009 | New features: - Support of AGC 3.50
- Support of PPM 3.03
- Support of PPU 3.00.1 and its variants
- Support of New N-Option board (M1)
- M-Logic items collapsible/expandable
- Device ID visible on the status bar
- Connected device versus USW file compatibility check
Changes: - Dedicated GPU Hydro device overview
- Supervision legend improved
- Colour Scheme Editor in Supervision improved
- Improvements to Translations
- Improved high alarm handling when using an older USW file
- N-option button only shown for supporting devices
|
3.13.0 | 15/10/2009 | New features: - Support of PPU3 and its variants.
- Search facility on the Parameters view.
- File association and distinctive icon for USW files.
- Dynamic legend on the Application Supervision view.
- Adjustable Polling delay for TCP-IP communication.
Changes: - Performance boost in M-Logic loading.
- Parameters view improvements.
- Translations view: Extended Character dialog improved.
- Support of 20 configurable views in the AGC 3.4xx
- Plant view for the gen-set mode “Mains Power Export” improved.
|
3.12.1 | 13/07/2009 | Changes: |
3.12.0 | 15/06/2009 | New features: - Application configuration and Supervision works with up to 256 Gen-sets as supported by the G7 option in AGC 3.40
- In Application Supervision three colors are used to indicate the state of the Gen-sets and bus-bars
- Device IDs can be changed in Application Configuration
- Support of TCP-IP Modbus communication through gateway to AGC or PPM without N-option card.
- New command line parameter BATCHWRITE, which perform a batch write operation with the project file provided by the argument of the OPENFILE parameter
Changes: - Enhancement of translations reading: Only available translations in the device are retrieved instead of all translations.
- Printing an application configuration from the USW will no longer cause it to close.
- When some multi-inputs are configured to digital inputs, their statuses are now updated in the Inputs/Outputs view.
- Various fixes and enhancements in Trending.
- Printing of translated strings is fixed.
- The USW version is shown in the title bar
|
3.11.1 | 24/03/2009 | New features: - User-customizable Read/Write timeouts: The connection-settings dialog allows the end-user to adjust various read/write timeouts.
Changes: - Support for PPM - 3.01.0.
- If a firmware upgrade fails, it is not possible to repeat this operation when the display shows “BOOT MODE, FLASH ERASED” (this applies only to USW 3.11.0).
|
3.11.0 | 18/02/2009 | New Features Corrections - Improvements in “Application configuration”
- Modification of “Enable” and “High alarm” columns in the parameter list
- Minor improvements to the plant view
- Scaling of plant view instruments at high voltage values improved
- Communication status improved
- Trending improvements
|
3.10.2 | 03/10/2008 | New features: - Added support for installation of new firmware for the AGC/PPM N-Options.
Changes: - Improved stability of the Modbus TCP/IP interface.
- Max tags in the N-Option feature ‘Advanced logging’ changed to 48.
|
3.10.1 | 18/07/2008 | New features: - Clicking on the logo at the top of the navigation bar will bring you to our homepage
- Outputs A & B are now shown as explicit texts in the parameter window and the printout
- After synchronization of the translations, untranslated and already translated texts are clearly indicated
Changes: - The commissioning panel is now active regardless of the value of the timer
- Writing a parameter file via a “batch write” will trigger a consistency check when appropriate
Corrections: - Status when performing a “batch read” operation updated
- Two fail class groups could appear when configuring an AOP
- Button 2 on an AOP template was not aligned correctly
- Behavior of the translations synchronization updated
- Error message when leaving the translations window removed
|
3.10.0 | 30/06/2008 | New features: - Plant configuration and supervision (AGC 3.30)
Changes: - Translation: Improvements in visualization and mask handling.
- Recently used file list handling updated.
- Placement of meters in AGC Dual main configuration adjusted.
- Input/Output window handling.
Corrections: - Trending: Gain on some values adjusted.
- Data tracer: Handling of ‘Unit names’
- Firmware download recovery mode.
|
3.00.30 | 19/03/2008 | - Backward compatibility improved for ‘.usw’-files including languages.
|
3.00.29 | 05/03/2008 | New features: - Translations are now part of batch operations.
- Support of all fonts/charsets (Display unit european and cyrillic, graphical display european/cyrillic and limited european/chinese).
- Extended characters dialog redesigned.
- Font selection dialog added (graphical display only).
- Baud rate negociated with the unit (GC-1F only) up to 115200 bauds.
- Communication type shown on the status bar (serial COMx, TCP-IP IP: x.x.x.x).
- Application software/firmware file extension automatically selected according to the connected unit.
Corrections: - Batch read/write: All AOP2s (ID 1 to 5) are readen/written instead of AOP2 ID 1 only.
- Parameters: When sending parameters stored in a project file, some parameter settings (configuration bits) could be overwritten in the unit.
- Parameters: Some items on the categories tab sheet could not be reached with mouse.
- Project file properties: Some hardware items could be duplicated.
- About window: Centered on the main monitor instead of the desktop (dual monitor systems).
|
3.00.27 | 11/10/2007 | Correction: - This USW release circumvents an issue present in the AGC firmware between release 3.10.2 and 3.21.0, where some parameters would not appear on the parameter list as expected.
|
3.00.26 | 20/09/2007 | New features: - The parameter inhibits are now shown on the parameter printout (only for parameters having inhibits defined).
- Parameter printout changed a bit (alternate colors).
- AOP1/2: Possibility to name individually leds and buttons (information saved in project file).
Changes: - AOP1/2: Leds and buttons drawing changed slightly. M-Logic rule enabled -> white background. M-Logic rule not enabled -> hatched white background.
- Parameter filtering modified.
Corrections: - When working on a saved parameter file (in a project file), and when editing a parameter, relays could appear as transducers.
- Faulty dependency check in I/O settings when working offline (information was based its dependencies on the device information).
|
3.00.25 | 13/07/2007 | - List of the most recently used project files added.
- Writing of translations improved
- Offline configuration of the AOP-1 and -2 improved
|
3.00.24 | 26/06/2007 | - Batch upload/download officially introduced (not in preview anymore).
- Save As feature
- Possibility to print all reports in A4 or Letter
- Option upgrade order form is now in english only
- AOP 1/2 printout refined
- Possibility to choose Modbus serial or TCP-IP
- Changes in the product database
- N-Option configurator
|
3.00.21 | 30/04/2007 | |
3.0.0.20 | 23/02/2007 | - Support of GC-1F product.
|
3.0.0.19 | 01/02/2007 | - Support of the latest AGC release 3.1.
- Usability of the parameter category filtering improved.
- Project file handling enhanced.
- Help file format changed.
|
3.0.0.18 | 17/10/2006 | |
3.31.0 | | Changes - Product updates: AGC-3, AGC 200, PPM-3, PPU-3, GPU-3, GPC-3, GPU-3 REC, GC-1F/2, AGC-4
- OEM options are removed from the Options page.
- OEM options are removed from the Option wizard.
- The user access level required for performing an update of the controller firmware of a GC- 1F is changed to "Customer".
- The keyboard shortcut “Alt+Tab” allows navigation back and forth between the USW and other applications even when a popup is open
- Trending allows only realistic sample rates.
New features - The Modbus Configurator (to set up the configurable memory area) is built into the USW
- Modbus configuration is included in the Batch Read/Write
- Notification sounds in case of alarms and batch operations.
- Custom logo can be used on printouts
- Broadcast progress is indicated in Application Configuration and Application Supervision (if supported by controller)
- New permission rule that prevents the user to see parameters that cannot be edited at current access level
|