DEIF’s RMC-142D stator earth fault relay protects genset operators against electric shock in case of earth faults in the generator’s stator.
The relay also protects against loss of excitation in case of earth fault in the stator.
The RMC-142D is part of DEIF’s complete range of relays for protection and control of generators featuring a number of adjustable parameters.
Variants
RMC-111D
- Short circuit
- I>>: 100 to 400 %. <50 mS response time
RMC-121D
- Short circuit
- I>>: 100 to 400 %. 2 sets of contacts (parallel)
RMC-122D
- Short circuit and over-current
- I>>: 100 to 400 %, I>: 50 to 150 %
- Combined functionality
RMC-131D
- Differential current
- I>>: 100 to 400 %. 2 sets of contacts (parallel).
Read more
You might also like
Over-/undervoltage relay, U> and U< RMV-142D
- Under- and Over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Single phase measurement.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Undervoltage relay, U< and U< RMV-132D
- Under-voltage (double).
- U<: 80 to 100 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Overvoltage relay, U> and U> RMV-122D
- Over-voltage (double).
- U>: 100 to 120 %,U>: 100 to 120 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Undervoltage and overvoltage relay, U< and U> RMV-112D
- Under- and over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Current relay RMC-122D
- Short circuit and over-current
- I>>: 100 to 400 %, I>: 50 to 150 %
- Combined functionality
- Short circuit relay (I>>)
- ANSI code 50 and 51
- Measurement of 3-phase currents
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Current relay RMC-131D
- Differential current relay
- ANSI code 87
- Measurement of 3-phase currents
- Non-stabilised measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- Extra change-over relay contact for signalling
- 35 mm DIN rail or base mounting