DEIF’s split-core current transformers are cost-saving and easy-to-install units for responsible and efficient energy management solutions and for retrofitting existing installations.
Because the split-core transformers can be mounted with a click and without interrupting the power supply, installation is smooth and executed in no time.
KBU is the ideal split core transformer for retrofit projects where DEIF covers the range from 100 A to 5,000 A.
Read more
You might also like
Current relay RMC-131D
- Differential current relay
- ANSI code 87
- Measurement of 3-phase currents
- Non-stabilised measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- Extra change-over relay contact for signalling
- 35 mm DIN rail or base mounting
Current relay RMC-122D
- Short circuit and over-current
- I>>: 100 to 400 %, I>: 50 to 150 %
- Combined functionality
- Short circuit relay (I>>)
- ANSI code 50 and 51
- Measurement of 3-phase currents
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Over-/undervoltage relay, U> and U< RMV-142D
- Under- and Over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Single phase measurement.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Undervoltage relay, U< and U< RMV-132D
- Under-voltage (double).
- U<: 80 to 100 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Overvoltage relay, U> and U> RMV-122D
- Over-voltage (double).
- U>: 100 to 120 %,U>: 100 to 120 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Undervoltage and overvoltage relay, U< and U> RMV-112D
- Under- and over-voltage.
- U>: 100 to 120 %, U<: 80 to 100 %.
- Under-voltage/over-voltage (U< + U>)
- ANSI code 27 and 59
- 3-phase measurement
- LED indication of fault condition
- Timer-controlled tripping
- LED indication for activated relay
- 35 mm DIN rail or base mounting
Synchronisation & circuit breaker closing FAS-113DG
- Automatic.
- Voltage regulation
- Breaker-time compensation.
- Synchronisation of generator to busbar
- Circuit breaker time compensation
- Voltage check
- LED indication of status
- LED for activated control
- LED for synchronising signal
- 35 mm DIN rail or base mounting
MTR-4 Multi-transducer MTR-4
- Suitable for all 1- and 3-phase network topologies
- Up to 1,000 VL-L AC input
- Accuracy class: 0.5 or 0.4
- Up to 4 analogue outputs
- Fast response time, less than 50 ms
- Measures more than 50 parameters
- RS-485 serial Modbus communication
- Fully configurable by USB, no aux. supply required
- Universal power supply of 20 to 300 V DC/48 to 276 V AC
Multi-functional protection relay MTR-4P
- Up to 1,000 V L-L AC voltage input
- Up to 20 A AC current input
- Accuracy class: 0.5
- Password protection
- Trip time typically below 50 ms
- Two-stage trip setting
- Start-up delay
- 13 different protection functions
- RS-485 serial Modbus communication
- Fast and simple commissioning and setup from M-set
- Universal power supply of 20 to 300 V DC/48 to 276 V AC
- Marine approval by GL/DNV
Protection & power management PPM 300 PPM 300
- Synchronization
- Marine certified Power Management - ABP: Advanced blackout prevention (32dg)
- PLC logic
- Engine and Generator protection
- Engine CANbus
- Rear mount
- Flexible Hardware
- Additional I/O racks (9 racks)
- Ethernet Ring connection for Power management
- Redundant breaker feedback
- Colour Display
- Emulation
- Marine approval
- Heavy consumer
- Fast load reduction
- Fuel optimisation